Compatibility · Oct 2026

Cartridge & turntable compatibility

Does this cartridge fit that tonearm? We work it out: resonance, counterweight and mounting, every combination with numbers and a clear verdict. 56 typical pairs from our top lists, all using the method of our Advisor. Orientation only; check the manufacturer’s specifications; errors excepted.

56 combinations Target 8–12 Hz Orientation · errors excepted Updated 3 Oct 2026

A cartridge can sound good and still be a poor match for the turntable. Tonearm and cartridge together form a spring-mass system, and its natural frequency should lie between about 8 and 12 Hz: low enough not to run into audible bass, high enough not to amplify record warps and footfall. A practical point comes on top: the arm’s counterweight must be able to balance the cartridge weight, and the cartridge must physically fit the arm.

On this page you will find 56 typical combinations from our top lists, with all intermediate steps. Every calculation uses the same function as our Advisor (German). The result reads “fits”, “borderline”, “does not fit” or “not verifiable”. You get numbers even when the verdict stays open: with Rega arms, for example, the resonance can be calculated, but the manufacturer names neither a weight range nor a mounting statement for third-party cartridges.

How we calculate

Resonance
fᵣ = 159 / √(mass × compliance). Mass = effective arm mass + cartridge weight + 1 g screws; compliance in µm/mN at 10 Hz.
Target zone
8–12 Hz is good, between 7 and 8 and between 12 and 14 Hz counts as a warning, outside 7–14 Hz as too far off.
100 Hz values
Many manufacturers specify the compliance at 100 Hz. We convert it to 10 Hz with a factor of 1.5–2.2 (middle 1.8) and show the range. Static-only values are converted with 0.5–0.8.
Counterweight
The cartridge weight must lie within the range the arm manufacturer gives for the counterweight. If balance is only possible with an auxiliary weight, the result is “borderline”.
Mounting
Half-inch cartridges need a half-inch mount (DIN IEC 98). If the mount is not documented, the result is “not verifiable”.
Verdict
One point outside: does not fit. Mounting or resonance open: not verifiable. One point at the edge: borderline. Otherwise: fits.
More
Full methodology

The 56 combinations at a glance

31 × fits 15 × borderline 7 × does not fit 3 × not verifiable

Sorted by turntable. Each pair has its own page with the calculation, input data, alternatives and questions.

Rega Planar 3

Tonearm Rega RB330, 11 g effective mass · Read the test

Pro-Ject Debut Carbon EVO

Tonearm Pro-Ject 8.6 Carbon (one-piece), 6 g effective mass · Read the test

Technics SL-1200GR2

Tonearm Technics universal arm (S-shaped), 8.5 g effective mass · Read the test

Pro-Ject Essential III

Tonearm Pro-Ject 8.6 aluminium, 8 g effective mass · Read the test

Pro-Ject Primary E

Tonearm Pro-Ject 8.6 aluminium (one-piece), 8 g effective mass · Read the test

Pro-Ject Debut PRO

Tonearm Pro-Ject 8.6 carbon/alu (one-piece), 10 g effective mass · Read the test

Pro-Ject X2 B

Tonearm Pro-Ject 9 carbon/alu sandwich, 13.5 g effective mass · Read the test

Pro-Ject RPM 5 Carbon

Tonearm Pro-Ject 9 EVO Carbon, 8 g effective mass · Read the test

Thorens TD 1500

Tonearm Thorens TP 150, 14.5 g effective mass · Read the test

SME Model 6

Tonearm SME M2-9, 9.5 g effective mass · Read the test

Pro-Ject T2 W

Tonearm Pro-Ject 9 aluminium, 9.5 g effective mass · Read the test

Thorens TD 202

Tonearm Thorens TP 71, 14 g effective mass · Read the test

Pro-Ject X8 Evolution

Tonearm Pro-Ject 9cc Evolution, 8.5 g effective mass · Read the test

Pro-Ject Signature 12

Tonearm Pro-Ject Signature 12 (12″, alloy headshell), 20.6 g effective mass · Read the test

Thorens TD 403 DD

Tonearm Thorens TP 150, 14.5 g effective mass · Read the test

Check your combination

In the Vinyl BotPro Advisor (German) you choose turntable and cartridge yourself and get the same calculation for every combination in our data, plus notes on phono preamp, amplifier and speakers.

Frequently asked questions

How do you check whether a cartridge fits a turntable?

We calculate three points: whether the mounting fits (half-inch mount), where the resonance frequency of tonearm and cartridge lies (target 8–12 Hz, warning outside 7–14 Hz) and whether the arm’s counterweight can balance the cartridge weight. The overall verdict is fits, borderline, does not fit or not verifiable.

What does “not verifiable” mean?

Then a documented figure is missing, usually the mounting type or the weight range of the counterweight. We do not guess; we state what is known, for example the calculated resonance, and what remains open. The Rega arms are an example, where the manufacturer gives no weight range.

How is the resonance calculated?

With fᵣ = 159 / √(mass × compliance). The mass is the effective arm mass plus cartridge weight plus 1 g for the screws; the compliance is referred to 10 Hz. If it is only given at 100 Hz we use 1.5 to 2.2 times that value; if only a static value exists, 0.5 to 0.8 times. The conversions result in a range.

Why are there only 56 combinations?

We only publish pairs for which arm mass and compliance are documented and which are typical (entry-level and upgrade combinations from our top lists). For every other combination in our data there is the Advisor, where you choose turntable and cartridge yourself.

Does the calculation replace the manufacturer’s specification?

No. It is an orientation based on published data, which can change or contain errors. Check the manufacturer’s specifications; errors excepted.

Orientation only; check the manufacturer’s specifications; errors excepted. Calculations by the AI Vinyl BotPro based on manufacturer data, without listening test and without measurement, not purchase advice in the legal sense. Notices & liability

Updated 3 Oct 2026 · Advisor data 2 Oct 2026 · Prices without guarantee, Oct 2026